CHQMH - FLUID, MAGNETIC PARTICLE INSPECTION, SUSPENSION MEDIUM

  • MSDS: CHQMH
  • Manufacturer: HOME OIL CO
  • Product Name: FLUID, MAGNETIC PARTICLE INSPECTION, SUSPENSION MEDIUM
  • National Stock Number: 6850-01-196-5472
Product Identification

Product ID:FLUID, MAGNETIC PARTICLE INSPECTION, SUSPENSION MEDIUM
MSDS Date:07/09/1998
FSC:6850
NIIN:01-196-5472
MSDS Number: CHQMH

Responsible Party
HOME OIL CO
3511 N OHIO
WICHITA, KS 67201
US

Emergency Phone: 316-838-4663/800-633-8253 (PERS)

Info Phone: 316-838-4663

Cage: 0A9L8

Contractor
HOC INDUSTRIES, INC
2609 WICHITA, KS 67219 US

Telephone: 316-838-4663

Cage: 0A9L8

Ingredients

PETROLEUM HYDROCARBON/SEVERELY HYDROTREATED LIGHT

CAS: 64742-47-8

RTECS: OA5504000

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: LIQUID CAUSES EYE
IRRITATION. SKIN: MAY CAUSE IRRITATION. RESPIRATORY SYSTEM: MAY
CAUSE SERVIOUS NERVOUS SYSTEM DEPRESSION. BREATHING OF VAPOR MAY
CAUSE IRRITATION. IRRITATES RESPIRATORY TRACT. INGESTION: MAY
IRRITATE SOMACH AND INTESTINES. IF SWALLOWED MAY BE ASPIRATED INTO
LINGS RESULTING IN PULMONARY EDEMA AND CHEMICAL PNEUMONITIS.
CHRONIC: REPEATED SKIN CONTACT MAY CAUSE A PERSIST ENT IRRITATION
OR DERMITITIS.
Explanation of Carcinogenicity:THIS PRODUCT IS NOT CURRENTLY LISTED AS
A CARCINOGEEN BY NTP, OSHA OR IARC.
Effects of Overexposure:RESPIRATORY SYSTEM: DIZZINESS, DROWSINESS,
HEADACHE, NAUSEA. MASSIVE OVEREXPOSURE MAY CAUSE UNCONSCIOUSNESS,
SLURRED SPEECH, OR CONVULSIONS IN HIGH CONCENTRATON OF VAPORS IN
CONFINED AREA. EYES: IRRI TATION. SKIN: IRRITATION. INGESTION:
IRRITATION OF STOMACH AND INTESTINES.
Medical Cond Aggravated by Exposure:NO DATA PROVIDED BY RESPONSIBLE
PARTY.

First Aid

First Aid:EYES- FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES.
GET MEDICAL ATTENTION. SKIN- REMOVE CONTAMINATED CLOTHING AND
SHOES. WASH EXPOSED CLOTHING AND SHOES. WASH EXPOSED AREA WITH SOAP
AND WATE R. IF IRRITATION DEVELOPS, SEEK MEDICAL ATTENTION.
INHALATION- REMOVE PERSON TO FRESH AIR. IF NOT BREATHING, GIVE
MOUTH-TO-MOUTH ARTIFICIAL RESPIRATION. INGESTION- HARMFUL IF
SWALLOWED! DO NOT INDUC E VOMITING. CALL DOCTOR IMMEDIATELY!

Fire Fighting

Flash Point Method:PMCC
Flash Point:=95.6C, 204.F
Lower Limits:1.0
Upper Limits:6.0
Extinguishing Media:USE NFPA CLASS B EXTINGUISHER FOR CLASS IB LIQUID
FIRES. DO NOT SPRAY WATER DIRECTLY ON FIRE.
Fire Fighting Procedures:EVACUATE AREA OF ALL UNNECESSARY PERSONNEL.
SHUT OFF SOURCE, IF POSSIBLE. WATER FOG OR SPRAY SHOULD BE USED TO
KEEP FIRE-EXPOSED CONTAINERS AND EQUIPMENT COOL. DO NOT SPRAY WATER
DIRECTLY ON FIRE.
Unusual Fire/Explosion Hazard:PRODUCT WILL FLOAT AND COULD BE REIGNITED
ON SURFACE OF WATER.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES INCLUDING
INTERNAL COMBUSTION ENGINES AND POWER TOOLS. VENTILATE AREA. AVOID
BREATHING VAPOR. USE SUPPLIED-AIR MASK FOR LARGE SPILLS OR IN
CONFINED AREAS. CONTAIN SPILL. REMOVE WITH INERT ABSORBENT. AVOID
CONTACT WITH EYES. AVOID ALLOWING PRODUCT FROM ENTERING STREAMS OR
SEWERS. REPORTABLE QUANTITY: NO (AS DEFINED IN 49 CFR 171.8).

Handling

Handling and Storage Precautions:TRANSPORT, HANDLE AND STORE IN
ACCORDANCE WITH 29 CFR (1910.106) AND APPLICABLE DOT REGULATIONS.
GROUND AND ELECTRICALLY INTERCONNECT CONTAINERS FOR TRANSFER. USE
SPARK PROOF TOOLS.
Other Precautions:MAGNETISM: NOT APPLICABLE. CORROSION RATE: NOT
CORROSIVE TO METALS.

Exposure Controls

Respiratory Protection:USE NIOSH-APPROVED RESPIRATORY PROTECTION.
Ventilation:LOCAL EXHAUST VENTILATION RECOMMENDED.
Protective Gloves:CHEMICAL AND PETROLEUM RESISTANT.
Eye Protection:CHEMICAL TYPE GOGGLES MUST BE WORN. DO NOT WEAR CONTACT
LENSES.
Other Protective Equipment:PROTECTIVE CLOTHING SUCH AS UNIFORMS SHOULD
BE WORN.
Work Hygienic Practices:FOLLOW SAFE WORK PRACTICES. WASH HANDS PRIOR TO
EATING OR SMOKING.
Supplemental Safety and Health
UNIT CONTAINER: 5 GALLON METAL CAN. HAZARDOUS ITEM: NO. EMERGENCY
TELEPHONE NUMBER FOR ACCIDENTS OR SPILLS: 1-800-633-8253 (PERS).

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:450-550F
Vapor Pres:0.4 @ 100F
Vapor Density:6.2
Spec Gravity:0.82 @ 60F
Viscosity:2.3 CST
Evaporation Rate & Reference:NO INFORMATION FOUND
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS, NO ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, WILL REACT VIOLENTLY.
Stability Condition to Avoid:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Hazardous Decomposition Products:CARBON MONOXIDE.

Disposal

Waste Disposal Methods:INCINERATE OR PLACE IN RCRA PERMITTED WASTE
MANAGEMENT FACILITY OBSERVING LOCAL, STATE, AND FEDERAL
REGULATIONS. WASTE CLASSIFICATION OF PRODUCT: NONE.

Toxicology

Toxicological Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.

Other Information

======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:NO DATA PROVIDED BY RESPONSIBLE PARTY.

Transport

Transport Information:TRANSPORTATION: TRANSPORT, HANDLE AND STORE IN
ACCORDANCE WITH 29 CFR (1910.106) AND APPLICABLE DOT REGULATIONS.
GROUND AND ELECTRICALLY INTERCONNECT CONTAINERS FOR TRANSFER. USE
SPARK PROOF TOOLS. DO T PROPER SHIPPING NAME: NOT REGULATED.DOT
HAZARD CLASS (IF APPLICABLE): NOT APPLICABLE. LABELS NEEDED: NONE.
DOT SPECIFICATION CONTAINER: NONE. DOT EXEMPTION NUMBER: NOT
APPLICABLE. LIMITED QUANTITY: NOT APPLICABLE. THIS MAGNETIC
PARTICLE INSPECTION FLUID CAN BE SENT THROUGH THE U.S. MAIL.

Regulatory

SARA Title III Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Federal Regulatory Information:THIS PRODUCT IS LISTED ON THE EPA/TSCA
INVENTORY OF CHEMICAL SUBSTANCES.
State Regulatory Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.